GPS

DGC-III NIBP AND SPO2 PATIENT MONITOR

★. Three Parameters: NIBP,SPO2,Pulse Rate

Features:

★. Compact, light, easy for carrying and handling.

★. Large bright LED display of measurement, easy to read.

★. Unique character and icon display of information, easy for setting and watching.

★. Storage and review of NIBP and SpO2 data up to 800 groups.

★. Build–in rechargeable LI-battery for 10 working hours.

★. Low battery power indicator.

★. Automatic power-off.

★. Audio and visual alarm.

★. External printer available.

★. H.S.Code: 90181930

★. Dimension: 200x205x95mm

★. Net Weight: 1.1kg  

★. Gross Weight: 2.9kg

★. Package Size: 360x330x175mm

★. Color: White

Standard Packing List:

NIBP&SPO2 Patient Monitor main unit 1pc 

Adult finger SPO2 sensor 1pc 

Adult NIBP cuff 1pc  

NIBP extension tube 1pc

AC power adaptor 1pc

Selectable Accessory:

Child finger/toe SPO2 sensor

Child NIBP cuff

Printer  

Technical Specifications:

(1) General Specifications

Size: 205mm×200mm×95mm

Weight: 1 kg

Display Specification

Parameter Display: 7-segment LEDs

 Information Display: Fixed characters and icons lighted by single-color LEDs

Power Supply Indicator: Dual-color LED

(2) Power Supply

AC Power Adaptor

Input: 100-240VAC, 50/60Hz

Output: DC 9V,800mA

Battery

 Lithium-ion rechargeable 5AHr 7.2V battery 

Operating time: 10 hours with full battery capacity.

(Condition: 25℃, NIBP working period is 10 minutes.)

Recharge Time: 20 hours.

(3) Environment

Temperature

Working: 0 ~ 45 (°C)

Transport and Storage: -25 ~ 85 (°C)

Humidity

Working: 30% - 85 %

Transport and Storage: 30% - 95 % (no condensation)

(4) Monitoring Parameter

NIBP

Method: Oscillometric

Mode: Manual, Auto, STAT

Measuring Interval in AUTO Mode: 1, 2, 3, 5, 10, 15, 20, 30, 60 (min)

Measuring Period in STAT Mode: 5 min

Cuff Pressure Range: 0 - 300 (mmHg)

Pulse Rate Range: 30 - 250 (bpm)

Measurement Rage: Adult 30-255mmHg, Pediactri 30-160mmHg

Over-pressure Protection: Adult 300mmHg, Pediactri 220mmHg

Pressure Resolution: 1mmHg

The SYSTOLIC and DIASTOLIC values measured using this device shall be equal to those measured by trained medical personnel using cuff and stethoscope. The MEAN value measured using this device is equal to that measured using end artery blood pressure measurement device.

SPO2

SPO2%

Measuring Range: 35 - 99%

Resolution: 1 %

Accuracy: ±2 %(70% - 99%), unspecified (0% - 69%)

Pulse Rate

 Measuring and Alarm Range: 0~250bpm

Resolution: 1bpm

Accuracy: ±1bpm

Storage and Review

Storage Method: Store NIBP and SPO2 data each time after one NIBP measurement. Maximum Store Data of 800 groups.

(5) Printer (optional)

Type: Thermal microprinter

Record Width: 57 mm

Recording Types: Real-time printing and review data printing

AC Power Adaptor

Input: 100-240V,50/60Hz

Output: DC 5V, 3A

© 2009-2019 DRAGON GROUP CHINA

                               THE BEST LUCK CORNER